Article 680 Swimming Pools, Spas, Hot Tubs, Fountains, and Similar Installations
 

 
Subject - Article 680
Based on - NEC - 2005 EditionSwimming Pools, Spas, Hot Tubs, Fountains, and Similar Installations

October 5, 2007
This newsletter was sent to 13985 newsletter subscribers
 

Ask a Question |  Weekly Code GraphicQuizzes |  Free Stuff InstructorsOnline Training Products | Seminars | SubscribeUnsubscribe
[ image1 Post Comments | View Comments | Notify Me When Comments Are Added ] Web Page Version [Printer-Friendly]    

Article 680   Hi Res - Cable/DSL [5676Kb]
VIEWING Video FILE requires
Real Media Player [ FREE ]
Swimming Pools, Spas, Hot Tubs, Fountains, and Similar Installations

680.12 Maintenance Disconnecting Means

This rule was revised to clarify that the permanently installed pool, storable pool, outdoor spa and hot tub, or fountain equipment maintenance disconnecting means must now be “readily accessible.” The 2002 NEC only required the maintenance disconnect to be “accessible,” and within sight of the permanently installed pool, storable pool, outdoor spa and hot tub, or fountain equipment.

A maintenance disconnecting means is required for permanently installed pool, storable pool, outdoor spa, outdoor hot tub, or fountain equipment, other than lighting for these water bodies. The maintenance disconnecting means must be readily accessible and located within sight from the permanently installed pool, storable pool, outdoor spa, outdoor hot tub, or fountain equipment. Figure 680-1

Author’s Comment: Disconnects must be located not less than 5 ft horizontally from the inside walls of a permanently installed pool, storable pool, outdoor spa, outdoor hot tub, or fountain, unless separated by a solid fence, wall, or other permanent barrier [680.22(C)].



Figure 680-1
(Click on image to enlarge)

       
 

Click here to post a comment
[ View More Newsletters ] [ Send to a Friend ] [ Post Comments | View Comments | Notify Me When Comments Are Added ]

Copyright © Mike Holt Enterprises, Inc. All rights reserved.
This article is protected by United States copyright and other intellectual property laws and may not be
displayed or published on the internet without the prior written permission of Mike Holt Enterprises, Inc.

http://www.MikeHolt.com     1-888-NEC-CODE (1-888-632-2633)

Experiencing a Problem? Click Here

Comments
  • Does 110.26 apply ?

    Romeo Ethier

Reply to this comment
* Your Name:
   Your name will appear under your comments.

* Your Email:
   Your email address is not displayed.
* Comments:

Email Notification Options:
Notify me when a reply is posted to this comment
Notify me whenever a comment is posted to this newsletter