A Preventable Dockside Tragedy


 
By Kevin Ritz


Image1
Lucas Ritz: 1991-1999

We were a live-aboard family with three active children at a freshwater marina on a tributary of the Willamette River near Portland, Oregon. Other kids were already swimming in the cove because it was that kind of day—hot and lazy. This was a common practice by adults as well as children during the warm summer of 1999.
Our sons Ian, age 10, and Lucas, age eight, asked to swim with their friends. Permission was granted, subject to close adult supervision by parents including their mother, a graduate nurse. The boys were both wearing Type II PFD life jackets, so it was great fun and a presumably safe to play in the water. Our children were schooled in aquatic safety. Being young professional people, my wife, Sheryl, and I had taken every precaution we could for peace of mind in a water environment.
      
On the inside of the dock, the kids were having a great time floating down with the river current on an inner tube. Lucas moved away from the others toward his mother, who was keeping pace on the dock with the children’s water activity. As he approached the ladder to get out of the water, he let out a loud gasp, immediately rolling onto his back in his life jacket, apparently unconscious. Sheryl yelled to the other kids to help him and jumped into the water herself.

As the kids approached Lucas, they felt a slight tingly sensation in the water and immediately backed off. Upon hitting the water downstream from Lucas, Sheryl’s extremities went numb and she experienced extreme difficulty moving her limbs, which, at the time, she attributed to fear. Somehow, Sheryl managed to pull Lucas to the dockside where others assisted in getting him onto the dock.
I arrived moments later after hearing the commotion and, along with another onlooker, started giving him CPR, which we continued until the paramedics took over approximately 15 to 20 minutes later. Our beloved Lucas was pronounced dead at 6:30 pm at Portland’s Emanuel Hospital. One moment he was laughing and playing—an instant later, his short life was over, leaving our hearts broken forever.
As parents we suffered agonies of “how did this happen?” This question then turned into “why did this happen?” We relived every moment trying to sort out what we did or didn’t do. It was not until the next morning that we were able to start unraveling the pieces of the mystery. The first assumption was that he drowned. However, he was wearing the best life jacket money could buy, which kept his face out of the water even though he was unconscious. He was pulled from a floating position only moments after rolling onto his back and CPR was started immediately. Also, at no time during CPR could we detect a heartbeat and his color was good. Neither of these observations would indicate drowning.
 
As Sheryl was telling me what had happened, she said she had never been so fearful in her life as to have her extremities tingle and go numb to the point where she could hardly move while in the water. Ian then related to me for the first time that he also felt a tingling as he approached his brother. Upon hearing all this it seemed clear to me that he did not drown, but that somehow, some way, AC electricity was present in the water where the kids were swimming. Our Lucas had been electrocuted.
I then called the County Coroner’s office, requesting an autopsy if they had not already done so, because knowledge of the circumstances and common sense pointed to electrocution, not drowning. They argued that there were no burns on his body. I pointed out that Lucas had been in an electrolytic solution, which eliminated the resistance of the skin (ordinarily skin resistance results in burns when an individual is electrocuted on land). To my complete horror, they responded that they would not even know how to test for something like that.
I told them that testing was not difficult and that I was going to test the water in the area. I then called the local Sheriff’s Department and left a message telling them my suspicions. With my digital voltmeter, I went to the area where Lucas had been, put the negative lead to a ground, dropped the positive lead into the water, and immediately got AC voltage. I notified the Sheriff’s Department, reporting what I had found and that I wanted to get someone to confirm my test. They agreed to send out some deputies while I called in an electrician. He arrived later that morning, tracing the electricity to a powerboat that was in the area where the kids had been swimming.
Concerns about liability soon unleashed a stream of other investigators, all of whom were suddenly interested in determining the source of the current. The local utility company wound up sending a team. The owner and manager of the marina arrived. More deputies were called.
Meanwhile, the electrician and I continued our investigation, focusing on the powerboat. We found a 12V wire lying on top of an AC wire, which had gotten hot enough to melt its own insulation and that of the hot (black) AC wire. This put 120V AC into the entire ground system of the boat, including the engines and propellers. This, coupled with lack of an AC safety ground, forced the voltage and electrical current into the surrounding water.
Freshwater is not a good electrical conductor; therefore the AC was unable to reach ground at a sufficient current to potentially trip the breaker. Because of its high salinity, the human body is a much better conductor of electricity than freshwater. (Saltwater is more conductive than the human body, which explains why electric shock deaths have not occurred in saltwater.) As Lucas approached the ladder, he passed into the field of AC current and, for a brief moment, completed the circuit to ground. His heart was stopped instantly; the insidious path of electrical current took the life of our son.
At first we considered this a freak accident—a unique set of circumstances that just happened to us. But this event completely changed my life and my focus. I was determined to understand how this could happen and to do everything I could to keep it from happening again. I did not want anyone else to suffer the pain we had suffered.  I, with the collaboration of my business partner, wrote a couple articles for The American Boat and Yacht Council (ABYC), describing the accident and the action that I have taken to create public and professional awareness of the problem, to provide education and a better understanding of the concepts involved, and to encourage the following of the ABYC standards and the use of ground fault-type devices onboard boats and in marinas. 
I determined to enhance my own knowledge so that I would have a solid understanding of the workings of AC currents in freshwater environments. With Andy Tufts, my business partner, we have done that using many different avenues, not the least of which was with ABYC. We are now both ABYC Master Technicians. Also, the thrust of our marine business changed significantly from emphasis primarily on sales to one concentrating on keeping boats electrically safe using ABYC standards. Our business motto became “Safer Boating Begins With A Safe Boat.” On-line, I also started checking out freshwater drownings with the suspicion that many were possibly electrical current related.

Image2Much has happened in the years since and all of it good. The awareness of “electric shock drowning” as a serious freshwater issue has significantly increased. A USCG-funded ABYC grant implemented by Capt. David Rifkin and James Shafer has greatly added to the understanding of how AC current behaves in freshwater.
The truth is that most people electrically shocked in freshwater, unlike my son, are drowned. This is because of skeletal muscle paralysis caused by low levels of AC current using the body as part of its return path to its source. This is what Sheryl experienced when she jumped into the water to rescue Lucas. That she didn’t drown or get electrocuted was due to the voltage gradient of the electrical current from its source. She entered the water farther from the faulty boat leak than Lucas. Depending upon several bodily factors, a range of say 15 to 30 milliamps (mA) of AC current will create muscle paralysis, and the drowning of even good swimmers is the result. An AC current flow of around 100 mA will put the heart into fibrillation, and death will likely follow within seconds. This is a very serious problem, but it is preventable.
First and foremost, no one should go in the water at a marina. Signs should be posted on every pier warning people to stay out of the water. But, since not everyone will read this article and since people often ignore signs, (as happened in the case of 19-year-old girl in 2005), or may fall into the water accidentally, the only certain cure is to have GFCI-type devices installed on boats that would automatically interrupt the flow of electricity in the case of a fault. There have been at least 60 needless fatalities and 100 unwarranted casualties from freshwater electrically induced faults. The solution in the future may be ELCI’s (see sidebar).
The unfortunate reality is that currently there is no post-mortem evidence available to coroners to ascertain whether electricity was involved in a drowning. Nor do most law enforcement personnel have the technical skills or tools to investigate this type of accident. This lack of knowledge, training, and tools leads to questions about how many deaths have occurred due to faulty wiring on boats. Some time after Lucas’s death, two Multnomah County River Deputies and I conducted a random sampling of 50 boats in three freshwater marinas in the Portland area. We found 13 boats leaking potentially lethal electrical current into the water. A ratio of 26 percent of faulty boat wiring leads one to wonder if the number of reported electrical deaths in freshwater is only the tip of the iceberg. If you have any doubts about your boat, it should be inspected by an ABYC-certified technician. Do not depend on an electrician with experience only on land. Let’s boat safely and save lives.      
For more information, contact Kevin Ritz: kevintritz@gmail.com.

The Long-Term Solution: Equipment Leakage Circuit Interrupters (ELCi)
Lucas’s death will not have been in vain if my efforts and involvement with ABYC have played some small part in the creation of a new ABYC E-11 standard that would require the installation of an Equipment Leakage Circuit Interrupter (ELCI) device on boats (already required by code for land-based damp environments such as bathrooms, kitchens, hot tubs, etc.). In our situation, if the 120V AC ground wire had been bonded to the metal components on the boat (i.e. the negative side of the battery), the energizing of the 12V DC system with the 120V AC would have most likely tripped off the shore power breaker, severing electrical current flow. Or, if a Ground Fault Circuit Interrupter (GFCI) breaker had been installed by the marina ahead of the boat’s shore power, even 10 mA of current would have tripped it off. So, bottom line—if the boat had been properly wired with an ELCI device or the marina placed a GFCI in front of the shore power cord, our son would still be alive today.
Once adopted and implemented on a vessel, the ELCI device, along with ABYC E-11 compliance, coupled with other pertinent ABYC electrical standards, will significantly reduce the odds of an electrically induced death because of an onboard wiring problem. Following standards will not only keep people on the boat electrically protected, but those in the water around the boat will be safe as well. After the accident, GFCI breakers were installed on each of the marina’s shore power distribution points. The only problem has been with new people coming to the marina, who have tried to bypass the GFCI because their boats have electrical faults and they’re tired of resetting breakers.
My business partner and I did extensive research into this issue and have conducted seminars for law enforcement personnel and local, national, and international marine investigators. We also serve as a resource for several agencies if there is a suspicion that electricity might be a factor in a drowning. Our intent is to set up a website giving technical information on the functioning of electrical currents in freshwater. If this information had been available to us we would not be still grieving the loss of our son. If my story doesn’t say anything else, understand that a relatively simple fix could have prevented years of pain.

Original article published by: http://www.boatus.com/seaworthy/kritz.asp

 

Click here to post a comment

[ Post Comments | View Comments | Notify Me When Comments Are Added ]
[ View More Newsletters ] [ imageSend to a Friend ]

Bookmark and Share



Copyright © Mike Holt Enterprises, Inc. All rights reserved.
This article is protected by United States copyright and other intellectual property laws and may not be
displayed or published on the internet without the prior written permission of Mike Holt Enterprises, Inc.

http://www.MikeHolt.com     1-888-NEC-CODE (1-888-632-2633)

Experiencing a Problem? Click Here

 
Comments
  • I am amazed that we continue to read of these incidents when remedies are so readily available to prevent them. It seems that our efforts to improve electrical safety are often directed towards less pressing issues, allowing glaring deficiencies as this unattended.

    Paul Lazorko
    Reply to this comment

  • Thank you for this informative, yet so sad article. I am forwarding & or copying & mailing to friends, as I type this communication to you.

    Joe
    Reply to this comment

  • I wonder how much of this sad story is applicable to swimming pools, spas, saunas, fish ponds, or even mud puddles? Thank you for sharing your story.

    Brad Deal
    Reply to this comment

  • this is a terrible loss & my deepest sympathy for the loss For yrs as an electrician that does marine work on a regular basis I have witten letters to local state & federal authorities in reference to A.C. & D.C. conductor location & insulation requirements between the 2 I recomend 12 inch seperation & where tis cant be met then each system be ran through seal tight or simlar type of conduit. Another life lost due to nobody wanting to adapt this type of code

    Glenn Hewett
    Reply to this comment

  • Thank you I will pass this on to my apprentices and I will be using this article in my OSHA and CPR classes as well

    Vergeront@msn.com
    Reply to this comment

  • very informative article thank you

    arty
    Reply to this comment

  • Mr. Ritz,

    I am so sorry for the lost of your son Lucas . I hope that boaters & also people who rent areas to dock boats will read what you wrote . I never knew this could happen either . I think you should send it to local news papers .. to get the word out . Plus also companies who build boats . Maybe they can come up with something to install on all boats to make sure this never happens again . It was a heartfull lost for your family . But also a learning result because now we know what can happen . Thanks to your son and you for your research . Now Lucas will save lives ..again I am sorry for your lost . A mother of 2 sons .. Michele

    Michele
    Reply to this comment

  • Mr. Ritz,

    I am very sorry for the loss of your son, I know there are no words that anyone can say that will eaze your family's suffering. But perhaps the work you are doing now will help prevent a similar tradgety in the future.

    I believe that everyone buying a new or used boat should receive a copy of your article to read and every Government agency issuing new boat registrations should supply a copy with the renewal.

    Perhaps then people would not mind resetting their GFIC when it trips.

    Ken
    Reply to this comment

  • The physics mentioned concerning current in fresh water and reduced skin resistance are correct. However, the GFCIs proposed would cause more problems and injury than the possibility of electric shock, For example. you wouldn't put a GFCI breaker on a fire pump. Neither should you prevent a gasoline vapor purge unit from operating. Also, they wouldn't protect from independent on board systems. To protect a person in the water-where skin resistance is so low-you'd need a GFCI kicking at less than 10ma. A marina is a wet place-they'd be tripping all the time. Sure you could put GFCI's that kick at 50ma, but that would be eyewash to fool the lawyers.

    Bob
    Reply to this comment

  • I have a recommended solution to prevent this not so uncommon fatal condition. The cause is usually allways the same which involves leakage current from some defective device usually on board a boat connected to shore power in addition to defective wiring, grounding or incorrectly wired GFCI devices in the marinas power system. My recommendations includes a series of steps that can and should be taken by every marina owner to ensure this condition does not exist on their docks power system and steps to prevent it from occuring or re-occuring. For those recommendations please see my reply posted to Bob's comments dated January 26th. below. Thank you, Larry LeSueur CPQ, CBCP----BW&A, Atlanta, Ga

    Larry LeSueur CPQ, CBCP
    Reply to this comment

  • Good write up Larry. Yes back in the early days GFCI's were a pain. Now, yes you are correct, people do noyt wire them properly or provide the proper closures. Laziness, hurriedness 101! I 100% agree with you.

    Joseph
    Reply to this comment


Get notified when new comments are posted here
* Your Email:
 
        
 
Add Your Comments to this Newsletter
* Your Name:
   Your name will appear under your comments.

* Your Email:
   Your email address is not displayed.
* Comments:

Email Notification Options:
Notify me when a reply is posted to this comment
Notify me whenever a comment is posted to this newsletter