Smart Plugs? – or not?

Image1

According to data collected by the National Fire Protection Association (NFPA) every year in North America 82,500 major electrical related fires are reported - an additional 890,000 fires go unreported!

Current safeguards, like your breaker/fuse panel, Arc Fault Circuit Interrupters (AFCI), Ground Fault Circuit Interrupters (GFCI) and child shock protectors, provide adequate protection, but not enough, according to Inventor John La Grou.

La Grou’s SafePlug invention has been billed by some as the next generation in residential and commercial electrical delivery. It promises to prevent deadly accidents like house fires -- and to conserve energy by making the electrical systems in our homes “smart”.  It is a technology that combines microprocessors in power outlets and RFID tags in electrical plugs.

TED’s (Technology, Entertainment, Design) talk website has generated much open discussion about this new brand of electrical fault circuit interrupters: the cost involved in replacing receptacles; the concept that safety devices often don't produce a real increase safety because they induce people to behave in a more risky way; whether it would be better suited to businesses and hotels; whether the automation provided by a smart receptacle might be more consistent and effective for only a limited number of homeowners.

And of course, the big issue: whether the government should pass a regulation that imposes every outlet use a technology such as this - with a few hundreds patents and owned by one company!

Click here to post a comment
[ View More Newsletters ] [ Send to a Friend ] [ Post Comments | View Comments | Notify Me When Comments Are Added ]

Copyright © Mike Holt Enterprises, Inc. All rights reserved.
This article is protected by United States copyright and other intellectual property laws and may not be
displayed or published on the internet without the prior written permission of Mike Holt Enterprises, Inc.

http://www.MikeHolt.com     1-888-NEC-CODE (1-888-632-2633)

Experiencing a Problem? Click Here

 
Comments
  • hello i read all yours adds...very goog. i have a quiestion? by code whats the minimun distance between 120vac and 24 vac inside a VFD or starter. wiring low voltage like start stop, current censors etc.....i work as ems tech... thank you....

    lenny cordero
  • Reply from: Bob   
    If the wiring is inside the VFD itself the wiring is the manufactures call. Inside the VFD the low voltage can be tied to in the same bundle as the 120 if the manufacturer so decides and, in fact, it often is. However, the low voltage and the high voltage must enter the VFD in separate conduits or cables. In general the manufacturer takes responsibility for the wiring inside their devices. However, local codes almost always insist that the device have a listing label or laboratory certification.. When wiring these devices ALWAYS follow the manufacturers instructions. Added wiring, such as bypass starters, are under the NEC and the AHJ. .


Reply to this comment