This article was posted 05/20/2010 and is most likely outdated.

Mike Holt's Rating of the Electrical Industry - 2010
 

 

Topic - Safety
Subject - Mike Holt's Rating of the Electrical Industry - 2010

May 20, 2010
This newsletter was sent to 19149 newsletter subscribers

Ask a Question |  Continuing EducationQuizzes |  Free Stuff Instructors Products | Seminars | SubscribeUnsubscribe
[ image1 Post Comments | View Comments | Notify Me When Comments Are Added ]  

Mike Holt’s Rating of the Electrical Industry - 2010

Here’s your update! Mike’s “Safest States” ranking has become an annual report that is widely anticipated. In his continued dedication to safety, Mike’s analysis rates and assigns a safety grade to each of the U.S. states based on the state’s requirements for the electrical industry. The standard for measurement in these findings comes from the state-wide adoption of the requirement, and we do acknowledge that there may be counties within the states that may rate higher that are not reflected in the data reported.Image1

Congratulations to Minnesota, North Dakota, Oklahoma, Oregon, South Dakota and Wyoming for their “A+” rating. These states have set the standard for electrical safety by adopting the most current Code on a state-wide level, requiring licensing for Inspectors, Apprentices, Journeymen, Master Electricians and Professional Engineers, as well as requiring continuing education at the state level for all of these classifications.

We'd also like to congratulate Nebraska for being the most improved state. Their grade has gone from B to A- due to the adoption of the 2008 NEC which becomes effective in July 2010, and the requirement for PDH for Engineers, which we had not reported accurately in July 2009.

We acknowledge and congratulate all those states that continue to set high standards in electrical safety.

The chart below summarizes our findings. To find out how the 2010 grades were determined, click here or click on the map image to see the complete spreadsheet.

2010 Data
2009 Data
2007 Data

If you have updated information that you feel would change the rankings please let us know. Remember that all grades are based on the state standard.

State

2007

2009

2010

Change

Reason for Change

ALABAMA

B-

C-

C-

0

 

ALASKA

B

B+

A-

+1

PDH required for Engineers

ARIZONA

D

D

D

0

 

ARKANSAS

A-

A-

A-

0

 

CALIFORNIA

A-

A-

A-

0

 

COLORADO

C+

B-

B-

0

 

CONNECTICUT

A-

A-

A-

0

 

DC

C

C

C

0

 

DELAWARE

A-

B+

A-

+1

08NEC effective 11/11/09

FLORIDA

B+

B

B+

+1

08NEC effective 10/1/09

GEORGIA

B

B-

B-

0

 

HAWAII

B-

C

C

0

 

IDAHO

B+

B+

A-

+1

PDH required for Engineers

ILLINOIS

D

D

D

0

 

INDIANA

C-

C-

C-

0

 

IOWA

D

A-

A

+1

Inspectors req. CEUs

KANSAS

C-

D

D

0

 

KENTUCKY

A-

A-

A

+1

08NEC effective 9/1/09

LOUISIANA

C

C+

B-

+1

08NEC effective 1/1/2010

MAINE

A

A

A

0

 

MARYLAND

D

D

D

0

 

MASSACHUSETTS

A-

A+

A

-1

*No PDH required for Engineers

MICHIGAN

A-

A-

A

+1

08NEC effective 12/2/09

MINNESOTA

B+

A+

A+

0

 

MISSISSIPPI

D+

D+

D+

0

 

MISSOURI

D+

D

D

0

 

MONTANA

B

B

B

0

 

NEBRASKA

B+

B

A-

+2

08NEC effective 7/12/10;*PDH for Engineers

NEVADA

C-

C-

C-

0

 

NEW HAMPSHIRE

A-

A-

A-

0

 

NEW JERSEY

B+

A-

A-

0

 

NEW MEXICO

B+

B+

B+

0

 

NEW YORK

D+

D+

D+

0

 

NORTH CAROLINA

A

A

A

0

 

NORTH DAKOTA

A+

A+

A+

0

 

OHIO

A-

B+

B+

0

 

OKLAHOMA

A+

A+

A+

0

 

OREGON

A+

A+

A+

0

 

PENNSYLVANIA

C

C-

C

+1

Inspectors req. CEUs

RHODE ISLAND

A

A

A

0

 

SOUTH CAROLINA

B-

B-

B

+1

08NEC effective 7/1/09

SOUTH DAKOTA

A

A+

A+

0

 

TENNESSEE

B

B

B

0

 

TEXAS

B+

A-

A-

0

 

UTAH

A

A

A

0

 

VERMONT

B

B+

A-

+1

PDH required for Engineers

VIRGINIA

B+

A-

A-

0

 

WASHINGTON

A-

A

A

0

 

WEST VIRGINIA

B

B

B+

+1

08NEC effective 7/1/2010

WISCONSIN

A-

A-

A-

0

 

WYOMING

A

A+

A+

0

 

PUERTO RICO

B

B-

B-

0

 

*Previously reported incorrectly.


2010 Data
2009 Data
2007 Data

 

 

Click here to post a comment

[ Post Your Comments | View Comments | Notify Me When Comments Are Added ]
[ View More Newsletters ]

Bookmark and Share


Copyright © Mike Holt Enterprises, Inc. All rights reserved.
This article is protected by United States copyright and other intellectual property laws and may not be
displayed or published on the internet without the prior written permission of Mike Holt Enterprises, Inc.

http://www.MikeHolt.com     1-888-NEC-CODE (1-888-632-2633)

 

 
Comments
  • NC (The State I live and work in) should be getting an "F" grade, since our legislature passed a law in 2008 exempting "Industrial Machinery" from electrical inspections. this was done by people completely ignorant about electrical safety that ignored all warnings and testimony from our electrical safety experts.

    Greg Smith

Reply to this comment
* Your Name:
   Your name will appear under your comments.

* Your Email:
   Your email address is not displayed.
* Comments:

This newsletter is closed to new comments.

Email Notification Options:
Notify me when a reply is posted to this comment
Notify me whenever a comment is posted to this newsletter